Description
Wear as the non swiveling simple screws onto the lower foot/inlet valve
Wagner professional systems
Though they are considered low pressure units
professional stains and Shellac coverage
Most of the time
Outlet Valve Kit (PC+) Wagner 9250 965 / Amspray 2500 / SprayTech 2520 Wear as the non swivelingInstallation instructions are shown below. Replacement of the outlet valve may be necessary if your spray performance remains poor after having performed all the steps contained in the Spraying Troubleshooting section of the owner's manual. Replacing the Outlet Valve: Unscrew the outlet valve from the outlet valve housing using an adjustable wrench. Inspect the inside of the outlet valve housing (a). Clean any accumulated paint. Replace with a new